  mhp650 series ? medical safety approvals ? end fan, top fan & uchannel mechanical options ? -20 oc to +70 oc operation ? 5 v standby ? ac ok, remote on/off and active current share ? load dependant variable fan speed ? screw terminals ? 3 year warranty the mhp650 ac-dc power supply provides upto 650 w of output power in three mechanical packages to provide installation flexibility in a range of medical applications. the unit comprises of a main output with voltages from 12-48 vdc and two peripheral outputs providing a 12 vdc fan supply and a 5 vdc standby supply which can be utilitsed with the signals and control features of the unit to provide detection of loss of a c input and remote on/off control. multiple units can used in parallel via the current share facility, providing higher power solutions. inherently low earth leak age current, and conducted emc compliance to class b also simplify higher power system design. packaged in a compact 8 (203 mm) x 4 (102 mm) x 2.6 (65 mm) and carrying iec60601 family safety approvals, the mhp650 has a load dependant variable speed fan, is fully protected with overtemperature shutdown and provides full power from -20 oc to 50 oc and 50% power at +70 oc.
figure 1 2 xppower.com input characteristics input derating curve characteristic minimum typical maximum units notes & conditions input voltage - operating 85 115/230 264 vac derate output power < 90 vac. see fig. 1. input frequency 47 50/60 63 hz power factor > 0.9 en61000-3-2 class a compliant input current - no load 0.15/0.3 a 115/230 vac input current - full load 6.5/3.2 a 115/230 vac inrush current 40 a 230 vac cold start, 25 c earth leakage current 90/175 250 a 115/230 vac/50 hz (typ.), 264 vac/60 hz (max.) input protection t16 a / 250 v internal fuse in both line and neutral models and ratings end fan models (-ef) output voltage v1 max output current v1 fan supply v2 standby supply v3 max output power model number 12 v 50.0 a not available 5 v / 0.2 a 607 w mhp650ps12-ef 15 v 40.0 a not available 5 v / 0.2 a 607 w mhp650ps15-ef 24 v 27.0 a not available 5 v / 0.2 a 657 w mhp650ps24-ef 28 v 23.0 a not available 5 v / 0.2 a 651 w mhp650ps28-ef 36 v 18.0 a not available 5 v / 0.2 a 657 w mhp650ps36-ef 48 v 13.5 a not available 5 v / 0.2 a 657 w mhp650ps48-ef top fan models (-tf) output voltage v1 max output current v1 fan supply v2 standby supply v3 max output power model number 12 v 50.0 a not available 5 v / 0.2 a 607 w mhp650ps12-tf 15 v 40.0 a not available 5 v / 0.2 a 607 w mhp650ps15-tf 24 v 27.0 a not available 5 v / 0.2 a 657 w mhp650ps24-tf 28 v 23.0 a not available 5 v / 0.2 a 651 w mhp650ps28-tf 36 v 18.0 a not available 5 v / 0.2 a 657 w MHP650PS36-TF 48 v 13.5 a not available 5 v / 0.2 a 657 w mhp650ps48-tf u channel models output voltage v1 max output current v1 fan supply v2 standby supply v3 max output power (1) model number 12 v 50.0 a 12 v / 0.5 a 5 v / 0.2 a 601 w mhp650ps12 15 v 40.0 a 12 v / 0.5 a 5 v / 0.2 a 601 w mhp650ps15 24 v 27.0 a 12 v / 0.5 a 5 v / 0.2 a 651 w mhp650ps24 28 v 23.0 a 12 v / 0.5 a 5 v / 0.2 a 655 w mhp650ps28 36 v 18.0 a 12 v / 0.5 a 5 v / 0.2 a 651 w mhp650ps36 48 v 13.5 a 12 v / 0.5 a 5 v / 0.2 a 651 w mhp650ps48 1. u channel models require a minimum of 5.5 ms airflow from the system for cooling 90 85 264 input voltage (vac) 40 50 80 60 70 90 100 output power (%)
xppower.com 3 output characteristics characteristic minimum typical maximum units notes & conditions output voltage - v1 12 48 vdc see models and ratings table initial set accuracy 1 (v1) , 5 (v3) % 50% load, 115/230 vac output voltage adjustment 10 % v1 only. see mechanical details. minimum load 0 a start up delay 0.5 s 230 vac full load hold up time 20 ms drift 0.2 % after 20 min warm up line regulation 0.5 % 90-264 vac load regulation 1 (v1) , 5 (v3) % 0-100% load. transient response - v1 4 % recovery within 1% in less than 500 s for a 50-75% and 75-50% load step ripple & noise 1 % pk-pk v1: 20 mhz bandwidth overvoltage protection 115 140 % vnom dc. output 1 only, recycle input to reset overload protection 110 145 % i nom output 1 only, auto reset. see fig 2. short circuit protection auto recovery, hiccup mode temperature coefficient 0.02 %/?c overtemperature protection c protects unit from overtemperature. auto reset. output overload characteristic figure 2 typical v1 overload characteristic (mhp650ps12 shown) unit enters hiccup mode
xppower.com xxxxxxxxxx 4 general specifications efficiency vs load characteristic minimum typical maximum units notes & conditions efficiency 84 % see fig 3 & 4 isolation: input to output input to ground output to ground 4000 vac 1500 vac 500 vdc switching frequency 70/200 khz pfc converter / main converter power density 8.2 w/in 3 mean time between failure 260 khrs mil-hdbk-217f at 25 c gb weight 2.8 (1.25) lb (kg) see mechanical details signals & control mhp650ps12 figure 3 characteristic notes & conditions signals & control remote sense compensates for 0.5 v total voltage drop ac ok / power fail open collector referenced to negative sense, transistor normally off when ac is good (see fig. 5 & 8) ac ok: provides 5 ms warning of loss of output from ac failure remote on/off (inhibit/enable) uncommited isolated optocoupler diode, powered diode inhibits both v1 & v2 (fan supply) (see fig. 6 & 9) current share when more than one unit (with the same output voltage) is used in parallel to increase output current, the current share pins 5/6 of one unit should be connected to pins 5/6 of the other unit(s). this will force the current to share between the outputs. similarly pins 2/4 of each unit should also be connected as a ground reference. units share current within 10% of each other at full load. see fig 7. standby supply v3 isolated 5 v/0.2 a supply, always present when ac supplied. mhp650ps48 figure 4
xppower.com 5 figure 5 figure 6 ac ok/power fail remote on/off (inhibit) signals & control signals - parallel load & current share connection example - + - + - + - + v1 output v1 output v1 output - sense - sense + sense + sense - sense + sense current share current share mhp650psxx (1) mhp650psxx (2) mhp650psxx (3) load figure 7 ac ok collector pin 3 ac ok emitter pin 2 (-sense) power supply transistor on (<0.8 v): ac not ok transistor off (>4.5 v): ac ok j3 logic connector 330r 5 v standby return pin 10 5 v standby pin 9 max 12 v 20 ma sistor on (<0.8 v): not ok sistor off (>4.5 v): ok inhibit hi inhibit low inhibit hi pin 7 power supply 100 r 800 r 2-5 ma chassis j3 logic connector signal high: power supply off low or floating: power supply on signal high: power supply on low or floating: power supply off inhibit lo pin 8 5 v standby pin 9 5 v standby return pin 10 inhibit hi pin 7 power supply 100 r chassis j3 logic connector inhibit lo pin 8 5 v standby pin 9 5 v standby return pin 10 800 r 2-5 ma
xppower.com 6 ac ok collector pin 3 ac ok emitter pin 2 power supply (1) j2 connector 330r 5 v standby return pin 10 5 v standby pin 9 ok emitter pin 2 power supply (2) j2 connector ac ok emitter pin 2 power supply (3) j2 connector transistor on (<0.8 v): ac or dc ok transistor off (>4.5 v): ac or dc not ok ac ok collector pin 3 ok collector pin 3 figure 8 parallel ac ok connection parallel remote inhibit connection figure 9 psu 1 psu 2 psu 8 pin 7 pin 8 pin 7 pin 8 pin 7 pin 8 open or ttl high = psu on short circuit or ttl low = psu off
xppower.com 7 environmental temperature derating curve fan speed control characteristic minimum typical maximum units notes & conditions operating temperature -20 +70 c derate linearly from +50 c at 2.5%/c to 50% at 70 c. see fig 10. low temperature start up -40 c some specification parameters maybe exceeded until after 20 minutes warm up period. storage temperature -40 +85 c cooling integral variable speed fan load dependant. see fig 11. humidity 5 95 %rh non-condensing operating altitude 3000 m shock 3 x 30 g/11 ms shocks in both +ve & -ve directions along the 3 orthogonal axis, total 18 shocks. vibration single axis 10-500 hz at 2 g x 10 sweeps electromagnetic compatibility - immunity phenomenon standard test level criteria notes & conditions harmonic current en61000-3-2 class a esd en61000-4-2 3 a radiated en61000-4-3 3 a eft en61000-4-4 3 a surges en61000-4-5 installation class 3 a conducted en61000-4-6 3 a magnetic en61000-4-8 3 a dips and interruptions en61000-4-11 dip: 30% 10 ms a dip: 60% 100 ms b dip: 100% 5000 ms b en60601-1-2 dip: 30% 500 ms a dip: 60% 100 ms a 115 vac input requires 50% load derating otherwise criteria b dip: 100% 10 ms a dip: 100% 5000 ms b figure 10 figure 11 40 30 10 0 20 50 -20 output power (%) 60 70 80 90 100 0 +20 +40 +50 +60 +70 ambient temperature (oc) 0 50 0 fan speed (%) 100 25 50 75 100 output power (%)
xppower.com 8 electromagnetic compatibility - emissions phenomenon standard test level criteria notes & conditions conducted en55022 / en55011 level b radiated en55022 / en55011 level a voltage fluctuations en61000-3-3 safety agency approvals safety agency safety standard category cb report certificate #us/17354/ul, iec60601-1 ed 3 including risk management medical ul ul file # e146893, ansi/aami es 60601-1:2005 & csa c22.2 no. 60601-1:08 medical tuv tuv certificate # b11 09 57396 110, en60601-1:2006 medical ce lvd equipment protection class safety standard notes & conditions class i iec60601-1 ed 3 see safety agency conditions of acceptibility for details mechanical details - end fan (suffix -ef) vo+ vo- standard terminal block, m4 screw, 6 pins, 9.5 mm center torque 10.62 lbs-in (1.2 nm) standard terminal block, m3.5 screw 3 pins 9.5 mm center torque 10.62 lbs-in (1.2 nm) 9.18 (233.2) n e l 2.50 (63.5) v1 adjustment output on, led 1.95 (49.5) 2.49 (63.3) airflow pin 1 pin 9 pin 2 pin 10 j3: logic connector 0.87 (22.2) 2.86 (72.6) 6.53 (165.8) 8.00 (203.2) 4.00 (101.6) c l 2 x m3 thd both side faces 0.15 (3.8) max screw penetration max torque 4.0-5.0 lbs-in (0.45-0.57 nm) 4 x m3 thd 0.15 (3.8) max screw penetration max torque 4.0-5.0 lbs-in (0.45-0.57 nm) notes: 1. dimensions shown in inches (mm). 2. weight: 2.8 lb (1.25 kg). 3. j2 mating plug: jst part no. phdr-10vs, contact: 26-22 awg jst part no. sphd-001t-p0.5. j2 logic connector (jst b10b-phdss) pin function 1 + sense 2 - sense 3 ac ok/power fail 4 - sense 5 current share 6 current share 7 + inhibit 8 - inhibit 9 +5 v standby (v3) 10 5 v standby return (v3) means of protection category primary to secondary 2 x mopp (means of patient protection) iec60601-1 ed 3 primary to earth 1 x mopp (means of patient protection)
xppower.com xxxxxxxxxx 9 mechanical details mechanical details - top fan (suffix -tf) notes: 1. dimensions shown in inches (mm). 2. weight: 2.6 lb (1.2 kg). 3. j2 mating plug: jst part no. phdr-10vs, contact: 26-22 awg jst part no. sphd-001t-p0.5. standard terminal block, m4 screw, 6 pins, 9.5 mm center torque 10.62 lbs-in (1.2 nm) standard terminal block, m3.5 screw 3, pins 9.5 mm center torque 10.62 lbs-in (1.2 nm) vo+ vo- n e 8.00 (203.2) l 2.58 (65.5) 2.50 (63.5) 1.95 (49.5) 0.87 (22.2) 6.53 (165.8) 2.86 (72.6) 4.00 (101.6) pin 1 pin 9 pin 2 pin 10 j3: logic connector v1 adjustment output on, led airflow 2 x m3 thd both side faces 0.15 (3.8) max screw penetration max torque 4.0-5.0 lbs-in (0.45-0.57 nm) 4 x m3 thd 0.15 (3.8) max screw penetration max torque 4.0-5.0 lbs-in (0.45-0.57 nm) j2 logic connector (jst b10b-phdss) pin function 1 + sense 2 - sense 3 ac ok/power fail 4 - sense 5 current share 6 current share 7 + inhibit 8 - inhibit 9 +5 v standby (v3) 10 5 v standby return (v3)
xppower.com xxxxxxxxxx 10 26-aug-14 mechanical details - u channel (no suffix) notes: 1. dimensions shown in inches (mm). 2. weight: 2.4 lb (1.1 kg). 3. requires system airflow, see thermal considerations. 4. j1 mating plug: jst part no. phr-2, contact: jst part no. sph-002t-p0.5s. 5. j2 mating plug: jst part no. phdr-10vs, contact: 26-22 awg jst part no. sphd-001t-p0.5. vo+ vo- 8.00 (203.2) n e l system airflow required 2.46 (62.5) 2.86 (72.6) 4.00 (101.6) c l 1.95 (49.5) v1 adjustment output on, led standard terminal block m3.5 screw 3 pins 9.5 mm center torque 10.62 lbs-in (1.2 nm) standard terminal block, m4 screw 6 pins 9.5 mm center torque 10.62 lbs-in (1.2 nm) pin 1 j1: fan connector 6.53 (165.80) 0.87 (22.2) pin 1 pin 9 pin 2 pin 10 j3: logic connector 2 x m3 thd both side faces 0.15 (3.8) max screw penetration max torque 4.0-5.0 lbs-in (0.45-0.57 nm) 4 x m3 thd 0.15 (3.8) max screw penetration max torque 4.0-5.0 lbs-in (0.45-0.57 nm) j2 logic connector (jst b10b-phdss) pin function 1 + sense 2 - sense 3 ac ok/power fail 4 - sense 5 current share 6 current share 7 + inhibit 8 - inhibit 9 +5 v standby (v3) 10 5 v standby return (v3) j1 fan connector (jst b2b-ph-kl ( lf) (sn) pin function 1 +v 2 -v thermal considerations (u channel) in order to ensure reliable operation in the end use application the recommended component temperatures listed should not be exceeded. higher temperatures up to the maximum stated can be used but product lifetime may be reduced. temperature measurements (ambient 50 oc) component recommended temperature o c maximum temperature o c c55 capacitor 70 105 t302 transformer 90 120 c314 capacitor 70 105 d311 diode 100 120
mhp1000 series ? 1200 w high line output power ? rugged industrial construction ? variable speed fan for noise reduction ? -40 c to +70 c operation ? 5 v standby ? ac ok, remote on/off and active current share ? screw terminals ? 3 year warranty the mhp1000 ac-dc power supply provides upto 1200 w of output power in a compact rugged mechanical package, suitable for a range of medical applications. the unit comprises of a main output with voltages from 12-48 vdc and a 5 vdc standby supply which can be utilitsed with the signals and control features of the unit to provide detection of loss of ac input and remote on/off control. multiple units can be used in parallel via the current share facility, providing higher power solutions. inherently low earth l eakage current, and conducted emc compliance to class b also simplify higher power system design. packaged in a compact 9.5 (241 mm) x 5.9 (150 mm) x 2.4 (61 mm) and carrying iec60601 family safety approvals, the mhp1000 has a load dependant variable speed fan is fully protected with overtemperature shutdown and provides -40 oc start up with full power from -20 oc to 50 oc and 50% power at +70 oc.
figure 1 2 xppower.com input characteristics input derating curve characteristic minimum typical maximum units notes & conditions input voltage - operating 85 115/230 264 vac derate output power < 90 vac. see fig. 1. input frequency 47 50/60 63 hz power factor > 0.9 en61000-3-2 class a compliant input current - no load 0.35/0.5 a 115/230 vac input current - full load (1000 w) 10.9/5.3 a 115/230 vac inrush current 60 a 230 vac cold start, 25 o c earth leakage current 75/140 250 a 115/230 vac/50 hz (typ.), 264 vac/60 hz (max.) input protection t20 a/250 v internal fuse in both lines models and ratings output voltage v1 max output current v1 standby supply v2 max output power model number <180 vac >180 vac <180 vac >180 vac 12 v 83.0 a 5 v / 1.0 a 1001 w mhp1000ps12 15 v 67.0 a 5 v / 1.0 a 1010 w mhp1000ps15 24 v 42.0 a 50.0 a 5 v / 1.0 a 1013 w 1200 w mhp1000ps24 28 v 36.0 a 43.0 a 5 v / 1.0 a 1013 w 1200 w mhp1000ps28 36 v 28.0 a 34.0 a 5 v / 1.0 a 1013 w 1200 w mhp1000ps36 48 v 21.0 a 25.0 a 5 v / 1.0 a 1013 w 1200 w mhp1000ps48 90 85 264 input voltage (vac) 40 50 80 60 70 90 100 output power (%)
xppower.com 3 output characteristics characteristic minimum typical maximum units notes & conditions output voltage - v1 12 48 vdc see models and ratings table initial set accuracy 1 (v1) , 5 (v2) % 50% load, 115/230 vac output voltage adjustment 10 % v1 only. see mechanical details. minimum load 0 a start up delay 0.5 s 230 vac full load hold up time 20 ms drift 0.2 % after 20 min warm up line regulation 0.5 % 90-264 vac load regulation 1 (v1) , 5 (v2) % 0-100% load. transient response - v1 4 % recovery within 1% in less than 500 s for a 50-75% and 75-50% load step ripple & noise 1 % pk-pk v1: 20 mhz bandwidth overvoltage protection 115 145 % vnom dc. output 1 only, recycle input to reset overload protection 110 140 % i nom output 1 only, auto reset. see fig 2. short circuit protection auto recovery, hiccup mode temperature coefficient 0.02 %/?c overtemperature protection c protects unit from overtemperature. auto reset. output overload characteristic figure 2 typical v1 overload characteristic (mhp1000ps12 shown) 0 2 4 6 8 10 12 14 0 5 10 15 20 25 30 35 output current (a) output voltage (v) unit enters hiccup mode
xppower.com xxxxxxxxxx 4 general specifications efficiency vs load characteristic minimum typical maximum units notes & conditions efficiency 84 % see fig 3 & 4 isolation: input to output input to ground output to ground 4000 vac 1500 vac 500 vdc switching frequency 70/200/130 khz pfc converter / main converter / standby power density 8.9 w/in 3 mean time between failure 260 khrs mil-hdbk-217f at 25 o c gb weight 2.1 (940) lb (g) see mechanical details signals & control mhp1000ps12 figure 3 characteristic notes & conditions signals & control remote sense compensates for 0.5 v total voltage drop ac ok / power fail open collector referenced to negative sense, transistor normally off when ac is good (see fig. 5 & 8) ac ok: provides 5 ms warning of loss of output from ac failure remote on/off (inhibit/enable) uncommited isolated optocoupler diode, powered diode inhibits both v1 & v2 (fan supply) (see fig. 6 & 9) current share when more than one unit (with the same output voltage) is used in parallel to increase output current, the current share pins 5/6 of one unit should be connected to pins 5/6 of the other unit(s). this will force the current to share between the outputs. similarly pins 2/4 of each unit should also be connected as a ground reference. units share current within 10% of each other at full load. see fig 7. standby supply v2 isolated 5 v/1.0 a supply, always present when ac supplied. mhp1000ps48 figure 4
xppower.com 5 figure 5 figure 6 ac ok/power fail remote on/off (inhibit) signals & control ac ok collector pin 3 ac ok emitter pin 2 (-sense) power supply transistor on (<0.8 v): ac not ok transistor off (>4.5 v): ac ok j2 logic connector 330r 5 v standby return pin 10 5 v standby pin 9 max 12 v 20 ma v): v): inhibit hi inhibit low inhibit hi pin 7 power supply 100 r 800 r 2-5 ma chassis j3 logic connector signal high: power supply off low or floating: power supply on signal high: power supply on low or floating: power supply off inhibit lo pin 8 5 v standby pin 9 5 v standby return pin 10 inhibit hi pin 7 power supply 100 r chassis j3 logic connector inhibit lo pin 8 5 v standby pin 9 5 v standby return pin 10 800 r 2-5 ma signals - parallel load & current share connection example - + - + - + - + v1 output v1 output v1 output - sense - sense + sense + sense - sense + sense current share current share mhp1000psxx (1) mhp1000psxx (2) mhp1000psxx (3) load figure 7
xppower.com 6 ac ok collector pin 3 ac ok emitter pin 2 power supply 1 j3 connector 330r 5 v standby return pin 10 5 v standby pin 9 ok emitter pin 2 power supply 2 j3 connector ac ok emitter pin 2 power supply 3 j3 connector transistor on (<0.8 v): ac not ok transistor off (>4.5 v): ac ok ac ok collector pin 3 ok collector pin 3 figure 8 parallel ac ok connection parallel remote inhibit connection figure 9 psu 1 psu 2 psu 8 pin 7 pin 8 pin 7 pin 8 pin 7 pin 8 open or ttl high psu on short circuit or ttl low psu off
xppower.com xxxxxxxxxx 7 environmental temperature derating curve fan speed control characteristic minimum typical maximum units notes & conditions operating temperature -20 +70 c derate linearly from +50 o c at 2.5%/ o c to 50% at 70 o c. see fig 10. low temperature start up -40 c some specification parameters maybe exceeded until after 20 minutes warm up period. storage temperature -40 +85 c cooling 2 x integral variable speed fans load dependant. see fig 11. humidity 5 95 %rh non-condensing operating altitude 3000 m shock 3 x 30 g/11 ms shocks in both +ve & -ve directions along the 3 orthogonal axis, total 18 shocks. vibration single axis 10-500 hz at 2 g x 10 sweeps electromagnetic compatibility - immunity phenomenon standard test level criteria notes & conditions low voltage psu emc en61204-3 high severity level as below harmonic current en61000-3-2 class a esd en61000-4-2 3 a radiated en61000-4-3 3 a eft en61000-4-4 3 a surges en61000-4-5 installation class 3 a conducted en61000-4-6 3 a dips and interruptions en60601-1-2 dip: 30% 25 ac cycles a dip: 60% 5 ac cycles a 230 vac 100% load, 100 vac 50% load dip: 100% 0.5 ac cyles a int: >95% 5000 ms b figure 10 figure 11 40 30 10 0 20 50 -20 output power (%) 60 70 80 90 100 0 +20 +40 +50 +60 +70 ambient temperature (oc) 0 50 0 fan speed (%) 100 25 50 75 100 output power (%)
22-feb-13 xppower.com 8 electromagnetic compatibility - emissions phenomenon standard test level criteria notes & conditions conducted en55011/22 class b radiated en55011/22 class a voltage fluctuations en61000-3-3 safety agency approvals safety agency safety standard category cb report certificate #us/18260/ul, iec60601-1 ed 3 including risk management medical ul ul file # e146893, ansi/aami es 60601-1:2005 & csa c22.2 no. 60601-1:08 medical tuv tuv en60601-1:2006 medical equipment protection class safety standard notes & conditions class i iec60601-1 ed 3 see safety agency conditions of acceptability for details mechanical details c l 4.50 (114.3) 1.20 (30.5) pin 2 pin 1 pin 10 pin 9 detail a j3: logic connector 9.41 (238.9) bb bb bb 4 x m4-0.7 thd both side faces 0.15 (3.8) max screw penetration max torque 10.62 lbs-in (1.2 nm) 4 x m4-0.7 thd both side faces 0.15 (3.8) max screw penetration max torque 10.62 lbs-in (1.2 nm) airflow 1.33 (33.8) 6.70 (170.2) vo+ vo- l n a 9.48 (240.9) 5.90 (149.8) 2.91 (73.9) 1.20 (30.5) 1.47 (37.4) 9.55 (242.64) 2.40 (61.0) v1 adjustment output on, led standard terminal block, m4 screw 3 pins 0.37 (9.5) center torque 10.62 lbs-in (1.2 nm) standard terminal block, m6 screw, 4 pins 0.62 (16.0) center torque 26.0 lbs-in (2.94 nm) notes: 1. dimensions shown in inches (mm). 2. weight: 2.8 lb (1.25 kg). 3. j3 mating plug: jst part no. phdr-10vs, contact: 26-22 awg jst part no. sphd-001t-p0.5. j3 logic connector (jst b10b-phdss) pin function 1 + sense 2 - sense 3 ac ok/power fail 4 - sense 5 current share 6 current share 7 + inhibit 8 - inhibit 9 +5 v standby 10 -5 v standby means of protection category primary to secondary 2 x mopp (means of patient protection) iec60601-1 ed 3 primary to earth 1 x mopp (means of patient protection)


▲Up To Search▲   

 
Price & Availability of MHP650PS36-TF

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X